Sensors

Results: 647
Select Image Part # Mfr. Description Datasheet Availability Pricing (JPY) Filter the results in the table by unit price based on your quantity. Qty. RoHS
NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, -15 to 300 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 300 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 300 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 30 psi absolute, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 30 psi absolute, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certifie Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, -15 to 30 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 30 psi absolute, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 3 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 4000 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certified Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 5000 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 3000 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certified Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 300 psi absolute, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, -15 to 300 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 2000 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 200 psi absolute, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certifi Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi absolute, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi absolute, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi absolute, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certifi Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 100 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 15 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certified Ca Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 150 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, Certified Calibration Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, -15 to 60 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 750 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft, integral orifice, Certified C Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 5 psi gauge, 0.25% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1

NOSHOK Pressure Sensors - Industrial High Accuracy Fixed Range Pressure Transmitter, 0 to 5 psi gauge, 0.125% of span, non-linearity best fit straight line per IEC 61298-2 at reference conditions, 1 Vdc to 5 Vdc, 3-wire, 1/8 NPT male, integral cable 3 ft Non-Stocked Lead-Time 1 Week
Min.: 1
Mult.: 1